Orthopedic implants are like superheroes in modern medicine. They help people who have trouble moving, those with broken bones, and others whose lives aren't as good as they could be. Imagine this: someone who couldn't walk now walks easily because of a strong hip implant. A sports player gets back to their game after doctors fix their knee with special screws and plates. An older person gains their freedom back with a tough shoulder implant. These show just how important orthopedic implants are, making a big difference in people's lives and bringing healing and hope.
Once these metals enter the bloodstream, they have the potential to travel throughout the body, crossing barriers such as the blood-brain barrier (BBB) that typically protects the brain from foreign substances. Significantly high amounts of metal like iron, cobalt and chromium in the blood—common components of orthopedic implants—can exploit various pathways to reach the brain.
Metal Implants and the Blood-Brain Barrier
Metallosis can result from a combination of factors, including the patient's gait and how the orthopedic surgeon positions and aligns the implant components. For instance, improper placement or alignment of the implant can lead to increased friction and wear between metal surfaces, accelerating the release of metal particles into the surrounding tissues and bloodstream. According to Figure 1, The patient experienced a substantial release of titanium alloy debris from the failed total hip arthroplasty (THA) implant. This debris traveled through the surrounding tissues and eventually reached the bloodstream, leading to significantly elevated levels of titanium, aluminum, and vanadium in the serum. The histological examination of tissue samples, specifically the synovial-like interface membrane (SLIM), revealed abundant deposits of metallic microparticles and macroparticles This explains why choice of materials used in the implant plays a crucial role. Some older-generation metal-on-metal implants, particularly those made of cobalt-chromium alloys, are more prone to wear and corrosion compared to newer materials like ceramics or advanced metals. The wear and corrosion of these metal components can contribute significantly to the development of metallosis, highlighting the importance of proper surgical technique and the selection of appropriate implant materials in minimizing this complication.
Figure 1: The histopathological examination of the synovial-like interface membrane (SLIM) show areas of necrotic tissue mixed with metallic titanium alloy debris in a periprosthetic soft tissue. Surrounding these particles were layers of large immune cells called macrophages. Additionally, there were areas of bleeding (hemorrhage) and inflammation characterized by clusters of immune cells called foreign body giant cells, indicative of a significant immune response to the presence of metal particles.
Courtesy of Clinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska
Research conducted by the National Institute of Neurological Disorders and Stroke (NINDS) has revealed the intricate pathway through which metal implants, frequently utilized in orthopedic surgeries, navigate the complex blood-brain barrier to reach the brain. The blood-brain barrier, a selective membrane system designed to safeguard the central nervous system, can be traversed by certain substances, including metal ions, given specific conditions. Studies published in esteemed journals such as The Journal of Neuroscience and The Journal of Neurology have elucidated the mechanisms underlying this phenomenon. Metal ions released from implants enter the bloodstream and circulate throughout the body. These ions, particularly those of cobalt and chromium found in metal implants, can then undergo translocation across the blood-brain barrier, either through passive diffusion or active transport mediated by transport proteins such as transferrin receptors. Once within the brain parenchyma, these metal ions can interact with neural tissues, potentially triggering neuroinflammatory responses, oxidative stress, and cellular dysfunction. This process underscores the significance of understanding the molecular pathways involved in metal implant-induced neurotoxicity, emphasizing the need for comprehensive research to elucidate the potential neurological implications and ensure optimal patient care in orthopedic practice.
Impact
In a recent study from the Practical Teaching Centre at the School of Forensic Medicine, China Medical University, the study revolves around the potential risks associated with metal implants commonly used in orthopedic surgeries. These implants, which include nails, plates, and fixtures, primarily consist of iron and are used worldwide in millions of surgeries. The concern raised in the study pertains to the release of iron from these implants over time due to corrosion. This ionized iron can infiltrate the surrounding tissues and enter the bloodstream, eventually crossing the blood-brain barrier. The study poses an essential question: can this iron from implants pose a risk factor for neurological diseases? The researchers discovered a higher incidence of Parkinson's disease (PD) and ischemic stroke in patients with metal implants from orthopedic surgeries compared to those who underwent similar surgeries but without implants. They found increased concentrations of serum iron and ferritin in subjects with metal implants. Specifically, since 2009, out of 15,000 subjects who had orthopedic surgeries with metal implantation, the occurrence of PD was found to be 1.98%. In contrast, among 7,500 subjects who had surgeries without metal implants during the same period, the occurrence of PD was lower at 1.31%.
Research conducted by the Nuffield Department of Orthopaedics at the University of Oxford evaluated the repercussions of prolonged exposure to elevated metal levels, specifically focusing on the implications of metal-on-metal hip resurfacing. This surgical procedure involves the utilization of metal components for both the ball and socket portions of the hip joint during replacement surgery. Essentially, it's a method where damaged bone and cartilage within the hip joint are resurfaced with metal implants, preserving more bone compared to traditional hip replacements. The study's findings uncovered significantly heightened concentrations of cobalt and chromium in the blood of patients who had undergone metal-on-metal hip resurfacing when compared to those with conventional hip prostheses. Cobalt and chromium are metals commonly used in these implants. This increased metal concentration is noteworthy because these metals can potentially enter the bloodstream and reach other parts of the body, including the brain.
Intriguingly, indications of lower gray matter attenuation in the occipital cortex and a reduced optic chiasm area were noted in the metal-on-metal group. Gray matter attenuation refers to a reduction in the intensity of gray matter, which is a major component of the brain involved in processing information. The occipital cortex is the part of the brain located at the back of the head responsible for visual processing. The optic chiasm is a crucial structure where the optic nerves intersect, playing a vital role in vision. These observations suggest potential impacts on brain structure resulting from prolonged exposure to heightened metal levels.
The Role of Advanced Coatings
Researchers are making implants better by putting special coatings on them. These coatings are like protective shields that prevent problems like infections and implant loosening. They carefully choose materials that work well with the body, making the implants blend in seamlessly. They also add extra stuff to the coatings, like germ-fighting agents, to keep infections away. Through lots of testing, they make sure these coatings work great before using them in real surgeries, making implants safer and more effective for patients.
The study from Mahidol University's Center for Biomedical and Robotics Technology (BART LAB) highlights the significant progress made in implant coating materials and techniques. These advancements offer promising solutions to the challenges faced in orthopedic surgery, including implant-associated infections, aseptic loosening, and poor osseointegration. By focusing on functional combination coatings and incorporating antimicrobial agents, researchers are striving to enhance implant-tissue integration and prolong the lifespan of orthopedic implants. The development of coating matrices with increased biocompatibility, sustained-release kinetics, and antibacterial properties is a key focus area. The use of natural hydrogels, primary proteins, growth factors, and biomolecules as coating adhesives shows great potential in improving implant performance and reducing complications. However, researchers emphasize the need for thorough systematic analyses to evaluate the benefits, biocompatibility, toxicity, and sustainability of these coating materials. While existing coating techniques have shown success in vitro, the transition to clinical practice remains a challenge. Commercial viability, mechanical integrity, sustained-release kinetics, and host toxicity are crucial factors that must be considered in the design of coating matrices. Surgeons and researchers alike must be aware of the pros and cons of different coating techniques to make informed decisions and overcome current issues such as bacterial resistance and implant-associated complications.
Ensuring Safety and Long-Term Success
The impact of orthopedic implants on brain health emphasizes the need for research, monitoring, and advanced preventive measures in patient care. Orthopedic implants, while transformative in restoring physical function and alleviating pain, also pose potential risks, especially concerning their interaction with the brain.
Research studies have shed light on various aspects of this interaction, from the migration of metal ions through the blood-brain barrier to the potential neurological consequences of chronic exposure to elevated metal levels. Understanding the pathways through which these implants can reach the brain and the subsequent effects on neural tissues is essential for ensuring patient safety and optimizing long-term outcomes.
One crucial area of focus is the development of implant coatings and surface treatments aimed at reducing complications and enhancing implant stability. Innovations in material science and coating techniques hold promise in mitigating risks such as infection, aseptic loosening, and implant migration. Coatings that promote osseointegration and biocompatibility while preventing bacterial colonization are particularly valuable in improving implant performance and longevity.
Regular monitoring and follow-up appointments play a pivotal role in detecting early signs of implant-related complications. Healthcare providers must remain vigilant in assessing implant performance, addressing patient concerns, and providing education on implant care and warning signs. Patients, too, play an active role in their health by adhering to follow-up appointments, reporting any unusual symptoms promptly, and adopting healthy lifestyle practices that support implant integrity.
References
Bohara, S., Suthakorn, J. Surface coating of orthopedic implant to enhance the osseointegration and reduction of bacterial colonization: a review. Biomater Res 26, 26 (2022). https://doi.org/10.1186/s40824-022-00269-3
Fokter, Samo K., Živa Ledinek, Milka Kljaić Dujić, and Igor Novak. 2024. "Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation" Bioengineering 11, no. 3: 235. https://doi.org/10.3390/bioengineering11030235
Matharu VK, Matharu GS. Metal-on-metal hip replacements: implications for general practice. Br J Gen Pract. 2017 Dec;67(665):544-545. doi: 10.3399/bjgp17X693557. PMID: 29192099; PMCID: PMC5697529.
Xia M, Liang S, Li S, Ji M, Chen B, Zhang M, Dong C, Chen B, Gong W, Wen G, Zhan X, Zhang D, Li X, Zhou Y, Guan D, Verkhratsky A, Li B. Iatrogenic Iron Promotes Neurodegeneration and Activates Self-Protection of Neural Cells against Exogenous Iron Attacks. Function (Oxf). 2021 Jan 12;2(2):zqab003. doi: 10.1093/function/zqab003. PMID: 35330817; PMCID: PMC8788796.
Zheng W, Aschner M, Ghersi-Egea JF. Brain barrier systems: a new frontier in metal neurotoxicological research. Toxicol Appl Pharmacol. 2003 Oct 1;192(1):1-11. doi: 10.1016/s0041-008x(03)00251-5. PMID: 14554098; PMCID: PMC3982148.
Assessed and Endorsed by the MedReport Medical Review Board